Split System Installation in Sunshine

Sunshine is changing fast, and we work both sides of that change. Original post war family homes around Hampshire Road and the station interchange, and the townhouse and apartment developments replacing them two and three to a block.

  • Sunshine 3020
  • Jemena network
  • REC 37223

The short answer

Split system air conditioning in Sunshine costs $2,500 to $7,500 installed. The original post war homes here have 2.4 metre ceilings and small separate rooms, which keeps individual capacities modest at 2.5 to 3.5kW per bedroom, while the new townhouses replacing them have higher ceilings, more glass and very little external wall space for indoor heads. Sunshine is inland, so no coastal corrosion allowance is needed. Reverse cycle heats a room for roughly 28 to 36 cents an hour.

Two outdoor air conditioning units installed down the side of a weatherboard home

From one of our jobs

Multi-head systems share one outdoor unit

Photographed on site in Melbournes west. REC 37223.

The post war homes are simple to condition: small separate rooms, low ceilings, modest volumes. The townhouses are trickier than they look, because modern insulation cuts the heat load but the layout leaves very few places to actually mount an indoor head or an outdoor unit.

Post war homes: small rooms, tired envelopes

The original Sunshine housing stock has 2.4 metre ceilings and separate rooms rather than open plan, which keeps volumes low. A bedroom is typically 2.5kW where the ceiling insulation is sound and 3.5kW where it is compressed, missing, or the room takes full western sun through a single glazed window.

The living room is usually 5.0kW, or 7.1kW where a wall has been removed to open it into the kitchen, which is the most common renovation in this suburb. Removing a wall changes the volume the system has to condition, and it is worth telling us at the quote if that is on your plans rather than after the unit is installed.

  • 2.5 kW bedroom

    Standard post war Sunshine bedroom with a sound ceiling and modest glazing.

  • 3.5 kW bedroom

    Where ceiling insulation is compressed or missing, or the room takes full afternoon western sun.

  • 5.0 kW living

    A separate lounge in an unrenovated post war plan with a doorway to the hall.

  • 7.1 kW opened up

    Where a wall has come out to join the lounge and kitchen, which is the most common Sunshine renovation.

Townhouses: nowhere to put anything

New Sunshine townhouses are built to current insulation standards, so the heat load per room is genuinely lower. What they lack is space. Double storey layouts with stairs eating the wall the head should go on, bedrooms with a window on one wall, a wardrobe on another and a door on the third, and a services area outside that already holds the hot water unit and the meter.

The result is that head and condenser placement decides the design more than capacity does. A multi head system with one outdoor unit is often the only way to serve several rooms. Where the internal wall available for a head faces a stairwell or a bulkhead, we may need a different unit style or a different wall entirely, which we work out on site rather than on paper.

Owners corporation approval and limited roof space

Townhouse and apartment developments almost always have an owners corporation, and anything mounted on a common wall or in a shared services area needs written consent. In most Sunshine developments there is a designated position and approval is straightforward when you use it.

The other thing worth knowing is that these dwellings have limited individual roof area, which matters if you were hoping to offset running costs with solar. A 3 to 5kW system is typical, and after normal household daytime use there is not much surplus. That does not change the case for reverse cycle, which is cheap to run regardless, but it does change what people expect from it.

What it costs to install and to run

Installed cost is $2,500 to $7,500 depending on capacity and head count. Reverse cycle returns 3 to 4 units of heat per unit of electricity, where gas converts only 80 to 92 percent of its fuel, so heating a room costs roughly 28 to 36 cents an hour instead of 50 to 72 cents for ducted gas, saving about $200 to $450 a year.

Victorian Energy Upgrades discounts come off the invoice directly, with no income test, on properties at least two years old, with a $200 including GST minimum customer contribution. Announced changes commence 30 September 2026 and amounts are confirmed at quote. Every indoor head needs a dedicated circuit and isolator, and original post war boards here frequently have no residual current protection and need replacing first.

Refrigerant work requires an ARC licence and the electrical connection requires a licensed electrician issuing a Certificate of Electrical Safety. We hold REC 37223 and carry out both parts ourselves, so the system is commissioned and running before we leave rather than waiting on a second trade, and our workmanship is guaranteed for 12 months.

On the ground

Sunshine specifics

  • Original post war homes here have small separate rooms and 2.4 metre ceilings, which keeps individual capacities modest. Opening the lounge into the kitchen, the most common local renovation, changes that calculation substantially.
  • New townhouses have better insulation but almost no usable wall space for indoor heads, so placement rather than capacity is what shapes the design.
  • Owners corporation consent is needed for anything on a common wall or in a shared services area. Most developments have a designated position and approval is routine when you use it.
  • Sunshine is well inland, so corrosion rated condensers are not required here. That is a genuine cost difference against the bayside suburbs we cover.
REC 37223SAA S3962281ABN 876892969375.0 from 63 Google reviews12 month workmanship guarantee

Licensed and accredited work by a local team. Read about Pivot Trade Services or see recent jobs across the western suburbs.

Answers

Sunshine questions

Tell us before, and ideally install after. Removing a wall increases the volume the system has to condition, often taking a room from 5.0kW to 7.1kW. A unit sized for the old layout will struggle in the new one. If the timing does not allow it, we can size for the finished plan and position the head where it will suit the future layout.

Get a Sunshine quote

Tell us the address and what you need. We quote Sunshine 3020 and the surrounding western suburbs in writing, with no obligation.

Free
On-site quotes
Fixed
Written pricing
12 mth
Workmanship guarantee